LS Industrial System Starvert Series, Fan & Pump Exclusive Use Sensorless Vector Control Frequency Inverter Drive, 11KW / 15HP, I/P: 3 Phase 380~480V, O/P: 3 Phase 380~480VAC, 0~120Hz
General Characteristics
Cooling method | Forced air cooling (Self-cooling for below 1.5KW-2, 2.2kW-4) | ||
Control | Control Method | V/F, Sensorless Vector, Slip Compensation, Easy Start Selectable | |
Frequency Setting Resolution | Digital Reference: 0.01 Hz (Below 100 Hz), 0.1 Hz (Over 100 Hz) | ||
Analog Reference: 0.01 Hz / 60 Hz | |||
Frequency Accuracy | Digital : 0.01% of the max frequency | ||
Analog : 0.1% of the max frequency | |||
V/F Pattern | Linear, Squared Pattern, User V/F | ||
Overload Capacity | 110% per 1 min, 120% 1 min | ||
Torque Boost | Manual Torque Boost (0~ 15%), Auto Torque Boost | ||
Operation Method | Kepad/ Terminal/ Communication Operation | ||
Operation | Frequency Setting | Analog: 0~12V / -12V / 0~20mA/ Pulse / Ext-PID | |
Digital: Keypad | |||
Input Signal | Start Signal | Forward, Reverse | |
Multi- Step | Up to 18 Speeds can be set including Job (Use Programmable Digital Input Terminal, Including Jog/Dwell | ||
Multi Step Accel/Decel Time | 0.1~ 6,000 sec, Max 4 types can be set via Multi- Function Terminal. Accel/Decel Pattern: Liner, U-Curve, S-Curve Selectable | ||
Emergency Stop | Interrupts the Output of Drive | ||
Jog | Jog Operation | ||
Fault Reset | Fault Reset | ||
Output Signal | Operating Status | Frequency Detection Level, Overload Alarm, Stalling, Over Voltage, Drive Overheating/Running/ Stopping/ Const ant running, Drive By-Pass, Speed Searching | |
Fault Output | Contact Output (3A, 3C, 3B) - AC 250V 1A, DC 30V 1A | ||
Indicator | Choose 2 from Output Frequency, Output Current, Output Voltage, DC Link Voltage (Output Voltage: 0~ 10V | ||
Operation Function | DC Braking, Frequency Limit, Frequency Jump, 2nd Function, Slip Compensation, Reverse Rotation Prevention, Auto Restart, Invert By-Pass Auto- Tuning PID Contral Start Stop Braking leakage Pre-PID Dual- PID MMC Start Prer By Pass, Auto Tuning, Control, Flying Start, Safety Stop, Flux Braking, Low leakage,Pre PID, Dual PID, MMC, Eay Start, e-heater | ||
Protection | Drive Trip | Over Voltage, Low Voltage, Over Current, Ground Fault, Drive Overheat, Motor Overheat, Output Phase Open, Overload Protection, External Fault 1, 2 , Communication Error, Loss of Speed Command, Hardware Fault, Option Fault etc | |
Drive Alarm | Stall Prevention, Overload Alarm, Thermal Sensor Fault | ||
Display | Keypad | Operation Information | Output Frequency, Output Current, Output Voltage, Frequency Set Value, Operating Speed, DC Voltage, Integrating Wattmeter, Fan ON time, Run-time, Last Trip Time |
Trip Information | Trip Indication when the Protection Function activates | ||
Max. 5 Faults are saved. | |||
Last Trip Time | |||
Environment | Ambient Temperature | -10 °C ~ 50 °C ( 14 °F ~ 122 °F ) | |
Decrease 2% of rated current for every 1 °C increase in above 40 °C | |||
Storage Temperature | -20 °C ~ 65 °C ( 14 °F ~ 149 °F ) | ||
Ambient Humidity | Below 90 % RH Max. (Non-Condening) | ||
Altitude-Vibration | Below 1,000m (3,300ft), Below 5.9/sec (0.6g) | ||
Application Site | Pollution degree 2, No Corrosive Gas, Combustible Gas,Oil Mist, or Dust |
Manufacturer | LS Industrial Systems |
---|---|
Brand | Autonics, Carlo Gavazzi, Crydom, Dupline, EOCR, Fairford, Hanyoung NUX, Heraeus, Honeywell, Kacon, Koino, Konics, LS Electric, Luxco, OEM, Qlight, Quantronix, Schneider Electric, TeSys |
Alliance Part No | AA-SV110iP5A-4 |
Mfr. Part No | SV110iP5A-4 |
Datasheet | Download |